Motor-Driven Metering Pump Sigma/ 2 (Basic Type)

Products

Motor-Driven Metering Pump Sigma/ 2 (Basic Type)

Technical Details

  • Stroke length: 5 mm,
  • Stroke length adjustment range: 0 – 100%
  • Stroke length adjustment: manually using self-locking rotary dial in 1% increments (optionally with actuator or control drive)
  • With the right, constant conditions, correct installation and calibration, precision exceeds ±1 %, based on maximum stroke volume.
  • Wetted materials: PVDF, stainless steel 1.4571/1.4404, special materials on request
  • Patented multi-layer safety diaphragm with optical diaphragm rupture display (an option with diaphragm rupture warning system via a contact)
  • Integrated hydraulic relief and bleed valve
  • A wide range of power end versions is available: Three-phase standard AC motor, 1-phase AC motor, motors for use in areas at risk from explosion and different flange designs for use in customer-specific motors
  • For areas at risk from explosion II 2G Ex h IIC T3 Gb X or II 2G Ex h IIC T4 Gb X (optional)
  • IP 55 degree of protection
  • High-strength fibreglass-reinforced plastic housing with excellent chemical resistance
  • For reasons of safety, provide suitable overflow devices during installation for all mechanically deflected diaphragm metering pumps.
description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Motor-Driven Metering Pump Sigma/ 2 (Basic Type)

Technical Details

  • Stroke length: 5 mm,
  • Stroke length adjustment range: 0 – 100%
  • Stroke length adjustment: manually using self-locking rotary dial in 1% increments (optionally with actuator or control drive)
  • With the right, constant conditions, correct installation and calibration, precision exceeds ±1 %, based on maximum stroke volume.
  • Wetted materials: PVDF, stainless steel 1.4571/1.4404, special materials on request
  • Patented multi-layer safety diaphragm with optical diaphragm rupture display (an option with diaphragm rupture warning system via a contact)
  • Integrated hydraulic relief and bleed valve
  • A wide range of power end versions is available: Three-phase standard AC motor, 1-phase AC motor, motors for use in areas at risk from explosion and different flange designs for use in customer-specific motors
  • For areas at risk from explosion II 2G Ex h IIC T3 Gb X or II 2G Ex h IIC T4 Gb X (optional)
  • IP 55 degree of protection
  • High-strength fibreglass-reinforced plastic housing with excellent chemical resistance
  • For reasons of safety, provide suitable overflow devices during installation for all mechanically deflected diaphragm metering pumps.